400 Amp Meter Base Wiring Diagram
Meter base ground must be unbroken from ground rod to ground connection in base.
400 amp meter base wiring diagram. 400 amp meter base correct wiring diagram. 60 amp overhead temporary construction service installation 100 amp mobile home overhead meter pole installation. 100 amp 200 amp underground service installation on house 400 amp 320 underground service installation. With ct metering there are several options.
Because utility configuration requirements vary widely eaton offers the widest range of utility approved sockets in the industry. Wouldn t this configuration allow up to a 400 amp continuous draw on the 320 amp meter and supply lines without protection. I am upgrading a 200 amp service to a 320 amp meter and adding a 2nd 200 amp panel. Ct metering is required for 400 amp and larger single phase 400 amp and larger 120 208 three phase and 400 amp and larger 277 480 three phase.
Single phase 400 amp electrical entrance on pole. Your local grover s sales team can advise you if this is the case in your area. Important wiring information consumer wires to straight load buss spades remc wires to curved line buss spades neutral wire buss spades 4 copper to ground rod spade. Pvc conduit can only be used on the load side of the disconnect box.
Ground wire must be in 1 2 thin wall conduit or 1 2 grey electrical pvc. This meter main is designed for larger residential and commercial applications and provides both a meter socket and main breaker. Class 320 meter breaker data wiring diagrams 62 64 table of contents b line series meter mounting equipment 1 eaton. Metering for 400 amp services or less.
The use of a transocket cts in switchgear see subsections 5 6 and 5 7 or overhead ct metering see subsection 5 8. Most of the wiring diagrams i have seen recommend installing 2 200 amp breakers off the meter panel and sending them to the 2 200 amp main lug breaker panels. Some areas do require the use of ct current transformer metering for a 400 amp service. Single meter sockets without bypass 400 amp max.
Weatherhead on outside of conduit and meter base meter base supplied by pcepa galvanized rigid metal conduit nipple no exceptions. Hi we put up a new pole barn. Eaton s b line business 509 west monroe street highland illinois 62249 0326. 200 amp overhead meter pole installation.
Meter sockets single position and multi position multi gang self contained meter sockets house the utilities electrical watthour meters in residential and commercial buildings. Underground h structure service installation. Mounting base details. Be sure to brace guy or concrete service pole.