Ac Disconnect Switch Non Fused Wiring Diagram
Step 2 prepare to wire the disconnect switch.
Ac disconnect switch non fused wiring diagram. Electrical ac dc 60a non fused disconnect wiring in a 20a non fused disconnect how do you wire the ground. Electrical disconnects are switches that isolate all wiring in a home or other building from the source of power typically the utility power service. If the current draw is 48 amps you will need a disconnect rated for 60 amps. Wiring diagrams 55 57 type s ac combination magnetic starters 58 59 class 8538 and 8539 58 59 3 phase size 0 5 58.
L1 or disconnect switch l2 l3 circuit breaker stop start m ot t1 t2 t3 m m solid state overload relay 1ct m m motor 3ct to 120 v. Eaton offers the industry s most complete line of acds. How to wire a disconnect. The disconnect is a non fuse puller type and is ul listed with an enclosed pull out.
Double break single break spst n c. Wiring your disconnect switch will vary slightly from one type of switch to another. Used to disconnect power from an air conditioning unit. If the current draw is 28 amps you will need a disconnect rated for 30 amps.
Make sure you use the proper size disconnect. A pull out disconnect switch gives a technician a safe way to work on high voltage appliances without the need to access the appliance s circuit breaker. The national electrical code requires that all appliances over 300 volt amps or over 1 8 horsepower use some sort of means of disconnect. Devices are available in fused non fused molded case switch or three phase designs and in metal or plastic enclosures for all application.
Make sure you use the proper size disconnect. One will ground a bare copper or green wire one will be neutral a white wire and one or two will be hot wires black or a combination of black and red. Step 5 cut hot wires. With the breaker turned off the wires can be disconnected and the cable removed from the e lectrical compartment of the.
I know the red black go to the main posts in and out. An air conditioning disconnect acd provides an installer or repair personnel with a visible disconnecting means while performing maintenance on an air conditioning unit. Depending on whether you have a 110v or 220v circuit you will have either 3 or 4 wires. The line side is the cable supplying voltage from your electrical panel.
Devices are available in fused non fused molded case switch or three phase designs and in metal or plastic enclosures for all application. Also called the service disconnect this is the first disconnect device after the utility meter. Fuse thermocouple single break spst n o. Quick videos explaining the difference between fused and non fused service disconnects.