Figure 1 is a schematic diagram of a distribution transformer for 120 240 v single phase service.
Distribution transformer connection diagram. All the diagrams are for additive polarity for three phase transformers. 240 x 480 secondary. To make the transformer connections compatible with three phase supplies we need to connect them together in a particular way to form a three phase transformer configuration. Delta wye three phase transformer connection.
However the required grounding electrode conductor is absent. 240 x 480 secondary. 120 240 2 2 1 2 anfc 4 2 2 bnfc x4 x1 h10 h2 h3 h1 x2 x3 h5 h6 h4 h7 h8 h9 connectconnect primary primary inter secondary. Figure 2 delta delta transformer connections click to expand diagram the connection diagram on the left shows how a delta delta connection can be made either with three single phase transformers or with one three phase transformer.
This separately derived system transformer has a compliant system bonding jumper. The dashed lines indicate the transformer outlines. Generalgeneral electrical connection diagramsacme transformer wiring diagrams primary. Conversely the y connection is used for stepping up to a high voltage as in generation station transformer.
The diagrams in this section of the general electric distribution transformer guide book covers the most common types of connections for single phase transformers and three phase transformers. The y connection is commonly used in stepping down from a high voltage to a medium or low voltage level as in distribution transformers. Distribution transformers 15 3 figure 15 3 two view construction standard detail of a conventional transformer to be installed on the distribution system. The grounding electrode makes the earth connection for the transformer secondary circuit.
The 240 v is obtained by making connections between the two ungrounded hot conductors and the 120 v is obtained by making connections between either of the two hot ungrounded conductors and the neutral grounded conductor. None x4 x1 h4 h3 h2 h1 x2 x3 connect connect primary primary inter secondary volts lines to connect lines to. Product literature and application advice were provided by abb. C57 12 70 terminal markings and connections for distribution and power transformers ansi c57 105 guide to three phase transformer connections distribution transformer manual by general electric rus by alexander publications and transformer connections by general electric.
It must be an effective connection and all grounding paths must be connected to it. 120 x 240 secondary. None x4x1 h4 h3 h2 h1 x2x3 primary. A transformer can not act as a phase changing device and change single phase into three phase or three phase into single phase.